Power terminal connections 20 to 6 AWG (0.5 to 10mm
2
), 630V
Printed circuit board conformally coated
Alarm two 24 Vdc, 350 mA each
* Rating based on heat sinks installed external to panel. Relay ratings have
a reduced rating when sinks are used internal to panel. Higher voltage rating
relays are also available as an option.
The RM6 has the following operating specifications:
Maximum storage temperature 185
F (85
C)
Minimum storage temperature -40
F (-40
C)
Oper. ambient temp. range -40
F (-40
C) to 158
F (70
C)
Terminal connections 28-12 AWG (0.14 to 2.5 mm
2
)
Earth leakage test connection 10-Pin header ribbon cable
Relay connection 40-Pin header ribbon cable
The RTB6 has the following operating specifications:
Maximum storage temperature 185
F (85
C)
Minimum storage temperature -40
F (-40
C)
Oper. ambient temp. range -40
F (-40
C) to 158
F (70
C)
Terminal connections 28-12 AWG (0.14 to 2.5 mm
2
)
Maximum RTD capacity six