Thermon ZP-L-WP Terminator Manuel d'utilisateur Page 5

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 8
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 4
Install power cable (if necessary).
Install quick mount terminal blocks and tighten screws (if
necessary).
Complete system wiring. Terminal set screws shall be
tightened to a torque value of 1.4 Nm (12.4 lb-in). See page
5 for wiring details.
Install junction box lid and twist hand tight. Insert screw-
driver into ratchet slots located on side of junction box base.
Use screwdriver to ratchet on junction box lid. Lid will rotate
30 degrees.
Lid latch mechanism fully engaged. To remove lid, repeat
steps 14 and 15 but in the opposite direction.
11.
13.
14.
15.
16.12.
Installation Instructions 4
Install IEK insulation entry kit to seal heating cable penetra-
tion through insulation cladding.
17.
Vue de la page 4
1 2 3 4 5 6 7 8

Commentaires sur ces manuels

Pas de commentaire